| Stir-Ator
Specifications - Corn Chart |
| |
|
| Bin
Size & Air Flow |
Bin
Size |
Fan
H.P. |
Drying
Rate
Multiplier*
For More Fans |
CFM
for
1 Fan |
Static
Pressure
for 1 Fan |
| 2
Fans |
3
Fans |
| 18 |
5.0
7.5 |
1.2
1.2 |
NA
NA |
6,600
7,100 |
3.5
3.9 |
| 21 |
5.0
7.5
10.0
12.5 |
1.2
1.2
1.2
1.2 |
NA
NA
NA
NA |
8,100
9,100
9,200
10,600 |
3.0
3.6
3.6
4.5 |
| 24 |
7.5
10.0
10C
12.5
15C
20C |
1.3
1.2
1.5
1.3
1.4
NA |
NA
NA
NA
NA
NA
NA |
10,200
11,000
11,300
12,000
13,100
15,500 |
2.8
3.2
3.3
3.6
4.1
5.3 |
| 27 |
7.5
10C
10.0
12.5
15C
20C
30C |
1.4
1.6
1.3
1.4
1.5
1.5
1.3 |
NA
NA
NA
NA
NA
NA
NA |
10,900
12,000
12,200
13,100
14,100
16,600
19,200 |
2.2
2.5
2.6
2.9
3.2
4.2
5.2 |
| 30 |
7.5
10C
10.0
12.5
15C
20C
30C |
1.6
1.7
1.5
1.5
1.6
1.6
1.6
|
NA
NA
NA
NA
NA
NA
NA
|
11,400
12,500
12,900
13,900
14,900
17,600
20,300 |
1.7
2.0
2.1
2.3
2.6
3.3
4.1
|
| 33 |
10C
10.0
12.5
15C
20C
30C |
1.7
1.6
1.6
1.6
1.6
1.6 |
NA
NA
NA
NA
NA
NA |
12,800
13,200
14,600
15,400
18,400
21,200 |
1.6
1.6
1.9
2.0
2.6
3.3 |
| 36 |
10C
10.0
12.5
15C
20C
30C |
1.8
1.7
1.7
1.7
1.7
1.7
|
NA
NA
NA
NA
NA
NA |
13,100
13,500
15,000
15,800
18,900
21,800 |
1.3
1.3
1.5
1.6
2.1
2.6
|
| 42 |
10.0
12.5
15.0
20C
30C
40C |
1.8
1.8
1.8
1.8
1.8
1.8 |
2.4
2.3
2.4
2.4
2.4
2.4
|
13,800
15,600
16,400
19,500
22,600
26,400 |
0.9
1.1
1.1
1.4
1.8
2.2 |
| 48 |
10.0
12.5
15C
20C
30C
40C
50C |
1.9
1.8
1.9
1.9
1.8
1.9
1.8 |
2.7
2.5
2.6
2.6
2.5
2.6
2.4 |
13,900
16,000
16,700
19,900
23,100
26,800
31,600
|
0.6
0.8
0.8
1.0
1.2
1.5
1.9 |
|
|
Corn
Drying Capacity (BU/24 hrs.)
and Recommended Number of Augers |
| Drying
Capacity (BU/24 hrs.) and Recommended Number of
Stirring Augers Heat Rise Above Ambient Temperature |
| 25° |
Augers |
50° |
Augers |
75° |
Augers |
100° |
Augers |
125° |
Augers |
360
490 |
1
1 |
750
810 |
1
1 |
1100
1180 |
2
2 |
1480
1590 |
2
2 |
1850
1990 |
3
3 |
450
500
510
580 |
1
1
1
1 |
920
1030
1040
1200 |
2
2
2
2 |
1350
1520
1530
1770 |
2
2
2
3 |
1810
2030
2060
2370 |
3
3
3
3 |
2270
2560
2580
2980 |
3
3
3
3 |
560
610
620
660
720
850 |
1
1
1
1
1
2 |
1160
1250
1280
1360
1490
1760 |
2
2
2
2
2
3 |
1700
1830
1880
2000
2180
2580 |
3
3
3
3
3
3 |
2280
2460
2530
2680
2930
3460 |
3
3
3
3
4
4 |
2860
3090
3170
3370
3680
4350 |
4
4
4
4
4
4 |
600
660
670
720
780
910
1060 |
1
1
1
1
2
2
2 |
1240
1360
1380
1490
1600
1880
2180 |
2
2
2
2
2
3
3 |
1820
2000
2030
2180
2350
2770
3200 |
3
3
3
3
3
3
4 |
2440
2680
2730
2930
3150
3720
4290 |
3
3
3
4
4
4
4 |
3060
3370
3430
3680
3960
4660
5390 |
4
4
4
4
4
4
4 |
630
690
710
760
820
970
1120 |
1
2
1
2
2
2
2 |
1290
1420
1460
1580
1690
2000
2300 |
2
2
2
2
3
3
3 |
1900
2080
2150
2320
2480
2940
3390 |
3
3
3
3
3
4
4 |
2550
2790
2880
3110
3330
3930
4540 |
3
4
4
4
4
4
4
|
3200
3510
3620
3900
4180
4940
5700 |
4
4
4
4
4
4
4 |
700
730
800
850
1010
1170 |
1
1
2
2
2
2 |
1450
1500
1660
1750
2090
2400 |
2
2
2
3
3
3
|
2130
2200
2430
2570
3070
3530 |
3
3
3
3
4
4 |
2860
2950
3260
3440
4110
4740 |
4
4
4
4
4
4 |
3590
3710
4100
4330
5170
5950 |
4
4
4
4
4
4 |
720
740
830
870
1040
1200 |
1
1
2
2
2
2 |
1490
1530
1700
1790
2140
2470 |
2
2
3
3
3
3 |
2180
2250
2500
2630
3150
3630 |
3
3
3
4
6
6 |
2930
3020
3350
3530
4220
4870 |
4
4
6
6
6
6 |
3680
3790
4210
4440
5310
6120 |
6
6
6
6
6
6 |
760
860
900
1070
1240
1450 |
2
2
2
2
2
3 |
1560
1770
1860
2210
2560
2990 |
2
3
3
3
3
4 |
2300
2600
2730
3250
3770
4400 |
3
3
4
6
6
6 |
3080
3490
3670
4360
5050
5900 |
6
6
6
6
6
6 |
3880
4380
4610
5480
6350
7410 |
6
6
6
6
6
6 |
760
880
920
1100
1270
1470
1740 |
2
2
2
2
3
3
3 |
1580
1810
1890
2260
2620
3040
3580 |
2
3
3
3
6
6
6 |
2320
2670
2790
3320
3850
4470
5270 |
3
6
6
6
6
6
6 |
3110
3580
3730
4450
5160
5990
7060 |
6
6
6
6
6
6
6 |
3900
4490
4690
5590
6490
7530
8800 |
6
6
6
6
6
6
6
|
|
*All
multiple fans are in parallel. Multiply drying rates x .66 for
10 point removal. Multiply drying rates x 1.61 for 4 point removal.
All multiple fan static pressures (where multipliers are shown)
fall within acceptable performance guidelines. |
| |
|
These
charts are based on ambient air temperature of 80° F, 60%
relative humidity, 16 feet of rice, 7% moisture removal (9%-12%).
These charts are designed as a guide only. Fan performance will
vary considerably from one manufacturer to another and other
factors can change the approximate bushels per day. Choose from
Stir-Ator models with one, two or three augers to fit bins from
18 feet to 48 feet. Each model gives you all the exclusive Stir-Ator
features that can turn a simple bin into a wet-holding tank,
dryer, and storage bin - all in one unit.
|
| |
|
| Stir-Ator
Specifications - Rice Chart |
| |
|
| Bin
Size & Air Flow |
Bin
Size |
Fan
H.P. |
Drying Rate
Multiplier*
For More Fans
|
CFM
for
1 Fan |
Static
Pressure
for 1 Fan |
| 2
Fans |
3
Fans |
| 18 |
5.0
7.5 |
1.4
NA |
NA
NA |
3,400
4,900 |
2.8
4.7 |
| 21 |
5.0
7.5
10.0
12.5 |
1.2
1.2
1.2
NA |
NA
NA
NA
NA |
5,700
6,200
6,200
7,800 |
3.8
4.2
4.2
5.7 |
| 24 |
7.5
10.0
12.5
10C
15C
20C |
1.2
1.2
NA
NA
NA
NA |
NA
NA
NA
NA
NA
NA |
7,500
7,600
9,300
9,500
10,600
12,900 |
3.9
3.9
5.1
5.2
6.0
7.9 |
| 27 |
7.5
10.0
12.5
10C
15C
20C
30C |
1.2
1.2
1.3
1.4
NA
NA
NA |
NA
NA
NA
NA
NA
NA
NA |
9,100
9,200
10,600
10,400
11,800
14,200
16,200 |
NA
NA
NA
NA
NA
NA
NA
|
| 30 |
7.5
10.0
12.5
10C
15C
20C
30C |
1.3
1.2
1.4
1.5
1.4
NA
NA
|
NA
NA
NA
NA
NA
NA
NA
|
9,900
10,600
11,700
11,100
12,800
15,300
17,600 |
NA
NA
NA
NA
NA
NA
NA
|
| 33 |
10.0
12.5
10C
15C
20C
30C |
1.3
1.4
1.6
1.5
1.4
1.2 |
NA
NA
NA
NA
NA
NA |
11,500
12,500
11,600
13,600
16,200
18,800 |
NA
NA
NA
NA
NA
NA |
| 36 |
10.0
12.5
10C
15C
20C
30C |
1.4
1.5
1.7
1.6
1.6
1.6
|
NA
NA
NA
NA
NA
NA |
12,300
13,200
12,100
14,300
17,000
19,700 |
NA
NA
NA
NA
NA
NA
|
| 42 |
10.0
12.5
15C
20C
30C
40C |
1.6
1.6
1.7
1.7
1.7
1.7
|
1.8
2.0
2.1
2.1
2.1
1.9
|
13,100
14,300
15,200
18,200
21,000
24,900 |
NA
NA
NA
NA
NA
NA |
| 48 |
10.0
12.5
15C
20C
30C
40C
50C |
1.8
1.7
1.8
1.8
1.5
1.8
1.7 |
2.1
2.2
2.3
2.3
2.0
2.3
2.1 |
13,400
15,000
15,800
18,900
24,900
25,700
29,700
|
NA
NA
NA
NA
NA
NA
NA |
|
|
Rice
Drying Capacity (BU/24 hrs.)
and Recommended Number of Augers |
| Drying
Capacity (BU/24 hrs.) and Recommended Number of Stirring
Augers Heat Rise Above Ambient Temperature |
| 10° |
Augers |
20° |
Augers |
30° |
Augers |
40° |
Augers |
290
420 |
1
1 |
420
600 |
1
1 |
530
770 |
1
2 |
640
920 |
1
2 |
490
530
530
670 |
1
1
1
1 |
700
760
760
950 |
1
2
2
2 |
890
970
970
1220 |
2
2
2
2 |
1070
1160
1160
1460 |
2
2
2
2 |
650
650
800
820
910
1110 |
2
2
2
2
2
2 |
920
930
1140
1160
1300
1580 |
2
2
2
2
2
3 |
1170
1190
1450
1480
1660
2020 |
2
2
3
3
3
3 |
1400
1420
1740
1780
1990
2420 |
2
2
3
3
3
3 |
790
790
910
900
1020
1230
1400 |
2
2
2
2
2
2
2 |
1110
1130
1300
1270
1440
1740
1980 |
2
2
2
2
3
3
3 |
1420
1440
1660
1620
1840
2220
2530 |
2
3
3
3
3
3
4 |
1700
1720
1990
1950
2210
2660
3030 |
3
3
3
3
3
4
4 |
850
910
1010
960
1100
1320
1400 |
2
2
2
2
2
2
3 |
1210
1300
1430
1360
1570
1870
2150 |
2
2
3
2
3
3
3 |
1550
1660
1830
1730
2000
2390
2750 |
3
3
3
3
3
3
4 |
1850
1990
2190
2080
2400
2870
3300 |
3
3
3
3
3
4
4
|
990
1080
1000
1170
1400
1620 |
3
3
3
3
3
3 |
1410
1530
1420
1660
1980
2300 |
3
3
3
3
3
3
|
1800
1950
1810
2120
2530
2940 |
3
3
3
3
3
4 |
2150
2340
2170
2550
3030
3520 |
3
3
3
4
4
4 |
1060
1140
1040
1230
1470
1700 |
3
3
3
3
3
3 |
1500
1610
1480
1750
2080
2410 |
3
3
3
3
3
3 |
1920
2060
1890
2230
2660
3080 |
3
3
3
3
4
4 |
2300
2470
2270
2680
3180
3690 |
3
4
4
4
6
6 |
1130
1230
1310
1570
1810
2150 |
3
3
3
3
3
3 |
1600
1750
1860
2230
2570
3050 |
3
3
3
3
3
4 |
2050
2230
2370
2840
3280
3890 |
3
3
3
3
4
6 |
2450
2680
2850
3410
3930
4660 |
3
3
3
6
6
6 |
1160
1290
1360
1630
2150
2220
2560 |
3
3
3
3
3
3
6 |
1640
1830
1930
2310
3050
3140
3630 |
3
3
3
3
6
6
6 |
2090
2340
2470
2950
3890
4020
4640 |
3
3
3
6
6
6
6 |
2510
2810
2960
3540
4660
4820
5560 |
3
3
6
6
6
6
6 |
|
*All
multiple fans are in parallel. Multiply drying rates x .66 for 10
point removal. Multiply drying rates x 1.61 for 4 point removal. All
multiple fan static pressures (where multipliers are shown) fall within
acceptable performance guidelines.
|